Fire and blast resistance

Durasteel ceilings provide horizontal barriers against fire and are tested and approved in accordance with the relevant criteria of BS 476: Parts 21: 1987 and 22: 1987.

Durasteel ceiling systems provide horizontal fire separation which are resistant to fire from above or below. Their high strength permits light loads such as maintenance foot traffic of up to 1.5kN/m² (point load) and service loads of up to 15kg/m².

Key Facts

4 Hour Fire Rated

Blast Resistant

Services Load (max): 15kg/m²

Point Load (max): 1.5kN/m²

40 Year Design Life

Fast, Dry Installation

Total ceiling protection

Blast rated systems are also available which are designed to 34kN/m² and typically used to provide increased fire and blast resistance to concrete slabs in areas such as basement substations where this is risk of significant structural damage to the structural levels above in the event of a fire or blast.

The exact build-up of the system depends on the performance requirements, but typically comprises of Durasteel boards secured to a steel channel framework, suspended on a hanger system from the slab above or fixed to the perimeter walls. Insulation can also be added where the heat radiation from the fire also needs to be limited.

The systems are highly resistant to impact and provide excellent resistance to high pressure hose streams during fire. They can be used in any situation where a horizontal separation barrier is required.

The system is ideal as a dividing barrier between building services and corridors, or for the formation of air plenums.

Technical Data

Suspended Ceilings

4 Hour Durasteel Suspended Ceiling Membrane (E240 – fire from below only)

Fire Rating: 240 minutes integrity-only

2 Hour Insulated Durasteel Suspended Ceiling Membrane (EI120 – fire from below only)

Fire Rating: 240 minutes integrity, 120 minutes insulation

4 Hour Insulated Durasteel Suspended Ceiling Membrane (EI240 – fire from below only)

Fire Rating: 240 minutes integrity & insulation

Self-Supported Ceilings

4 Hour Durasteel Self-Supported Ceiling (E240 – fire from below only)

Fire Rating: 240 minutes integrity-only

2 Hour Insulated Durasteel Self-Supported Ceiling (EI120 – fire from above or below)

Fire Rating: 240 minutes integrity, 120 minutes insulation

4 Hour Insulated Durasteel Self-Supported Ceiling (EI240 – fire from below only)

Fire Rating: 240 minutes integrity & insulation

Plenum Ceilings

1 Hour Insulated Durasteel Composite Membrane Plenum Ceiling (EI60 – fire from below only)

Fire Rating: 240 minutes integrity, 60 minutes insulation

Blast-rated Ceilings

4 Hour Fire & Blast Durasteel Ceiling (E240 – fire from below only)

Fire Rating: 240 minutes integrity-only

Blast Rating: 34kN/m²

4 Hour Insulated Fire & Blast Durasteel Ceiling (EI240 – fire from below only)

Fire Rating: 240 minutes integrity & insulation

Blast Rating: 34kN/m²

Clients we've worked with

Case Studies

Get in touch

Interested in starting a ceiling fire protection project with Invicta? Get in touch today to speak to our experts, and arrange a complimentary site visit.

Accreditations & Affiliations

Safecontrator Logo
SafeContractor Approved
ASFP Logo
FORS Bronze

For your information

You are being redirected to one of our divisional subsites which contains more detailed information on the required division. To navigate back to the main Invicta Group site, please click the link found in the footer at the bottom of the page.