30 Minute Insulated Durasteel Fire Barrier (E240, EI30)

Quick Quote

Contact Fraser Shearer Sarun Vysakham Ben Tan Anand Raghavan Anand Raghavan Our USA Office

To get a quotation or arrange a free site survey - Call Fraser Shearer Sarun Vysakham Ben Tan Anand Raghavan Anand Raghavan Our USA Office on

Or Send us a message

Quick Quote

Contact Fraser Shearer Sarun Vysakham Ben Tan Anand Raghavan Anand Raghavan Our USA Office

Home 30 Minute Insulated Durasteel Fire Barrier (E240, EI30)

Key Details

  • Fire resistance: 240 minutes integrity, 30 minutes insulation (E240 EI30)
  • Test standard: BS EN 1364-1: 1999
  • Fire attack: Both sides
  • Framework: 80mm x 60mm x 3mm (for heights up to 6m)
  • Overall depth: 118mm
  • Weight (nominal): 51kg/m2
  • Estimated sound reduction: 42dB
  • Maximum height: 3m

System Build-Up

  1. 9.5mm Durasteel sheet
  2. 80 x 60 x 3mm CRC at 1200mm centres
  3. M5.5 x 38mm self-drill, self-tap tek screws at max 200mm centres

Construction

Perimeter channels fastened to surrounding construction with M10 or M12 all-steel expanding anchors (or equivalent for alternative types of supporting construction) at 500mm maximum centres.

The vertical channels are set at a maximum 1200mm centres. Horizontal and vertical channel members either welded together or joined with steel angle cleats, minimum 60mm x 60mm x 3mm thick x 60mm long, fastened to each channel member with two M10 steel bolts and nuts.

9.5mm Durasteel sheets fixed on both sides of the channel with M5.5 steel self drill and tap Tek screws at 250mm nominal centres.

Fixings a minimum of 12mm from edge of sheet and a maximum of 50mm from corners. Length of fixing to be sufficient to ensure appropriate penetration of screw thread in accordance with screw manufacturer’s recommendations.

Vertical board joints coincide with studs, horizontal board joints are backed by steel channel the same size as the vertical studs.

Share/Like this page

Accreditations & Affiliations

SpecUp - System Specification Wizard

Answer the 5 short questions below to receive your recommended Durasteel system specifications. Hover over the ? icons for a brief explanation.

Question 1/5

Type of system required?

Question 2/5

Fire rating required?

Question 3/5

Fire integrity-only or integrity and insulation?

Question 4/5

Fire attack risk from one side or both sides of the system?

Question 5/5

Blast rating required in addition to fire rating?

Creating your results page

Thanks for completing the SpecUp, you’ll be redirected to your results shortly.

Click here if you aren't redirected after a few seconds

Start your project

Tell us about your project. Please complete this form. One of our sales team will come back to you with more details. If you prefer, you can drop us an email.





    Project details




    Attach any files that may assist us with your enquiry (specs, drawings, bill of quantities, etc.)

    Acceptable file types are .pdf, .jpg, .dwg, .xls, .xlsx, .doc, .docx, .zip and .rar up to a maximum of 15mb. For files larger than this, please use the external file upload link below.